ICCS Micro Gateway
Intelligence and control functionality come together in the ICCS CAN Gateways. They connect the CAN networks with different bit rates or protocols.
The smallest gateway module is packaged as a relay and provide connections for an analogue input, 2x CAN high speed and optionally a LIN bus interface. CAN messages of a network part can be received, filtered, edited and transferred to a connected subnetwork. Through the use of implementation and filtering rules, there is the option of a protocol adaptation between the subnetworks. The additional LIN bus connection (optional) enables data exchange between LIN and CAN networks.
Application Examples:
- CAN Bridge
- CAN message filtering
- LIN to CAN gateway
- LIN master or slave mode
- Connection of CAN-systems with different bus speeds
- Signal manipulation, event triggered suppressing and sending messages
- Connection of LIN sensor to the CAN bus, for example LIN rain, light, or battery sensor
General Information | |
---|---|
Connector | 9 Pins DIN |
Dimensions | 30 x 30 x 50 mm |
Weight | ~ 30 g |
Operating temperature | -40 °C to 85 °C |
Storage temperature | -40 °C to 85 °C |
EMC | E1 |
Ingress protection | IP 53 |
Operating Voltage Vsupply |
9 bis 30 V DC (CAN-CAN) 12 V DC (CAN-CAN-LIN) |
Pre-fusing | 1 A |
Current consumption | 60 mA |
Sleep mode consumption | <1 mA |
Processor type | Freescale HCS12 XEG |
Clock frequency | 100 MHz |
Flash memory | 128 kB |
RAM | 12 kB |
EEPROM | 1 kB available for graphical programming |
CAN Bus Interfaces | |
---|---|
Acc. ISO 11898-2 | High speed wake on CAN |
Acc. CAN 2.0 B | 29 Bits extended address identifier |
Acc. CAN 2.0 A | 11 Bits address identifier |
Baud rate |
20 kBit/s to 1000 kBit/s (125 kBits/s default value) |
Available inputs / outputs | ||
---|---|---|
1 | Analogue input | 0-33.67 V DC 12 Bit |
1 | Digital input | KL15 activation pin |
1 | LIN Bus | Optional LIN master |
Inputs / outputs details | |
---|---|
Analogue inputs | |
Input voltage max | Vsupply |
Measuring range | 0-33.67 V DC |
Resolution | 12 Bit |
Input resistance | 66.68 kΩ |
Input frequency | max 50 Hz |
LIN Bus (optional) | |
---|---|
Operating Voltage Vsupply (30) | 12 V DC only |
Pull up to Vsupply | 1 kΩ with protection diode |
Implementation | acc. LIN 2.1 |
Pin | Pin description | Function |
---|---|---|
1 | H2 | CAN Bus 2 High |
2 | 30 | Vcc Main Power Supply 9-30 V DC / 12 V DC |
3 | L2 | CAN Bus 2 Low |
4 | 15 | KL 15 Activation pin |
5 | LIN (opt.) | Optional LIN Bus |
6 | 31 | Ground |
7 | H1 | CAN Bus 1 High |
8 | Ana In | Analogue input 0-30 V |
9 | L1 | CAN Bus 1 Low |
Programming
Programming the ICCS Micro Gateway is carried out using ICCS SDK Plus software.
In the development phase, we support you in the creation of programs.
If you prefer to create your parameters or create programs by yourself try our software development kit ICCS SDK Plus which you can borrow for three month free of charge.
Datasheet
- ICCS Micro Gateway