ICCS Micro CAN
Overload protected high side outputs with PWM possibility or changeover relay output - In the ICCS Micro CAN product range you have the choice. The modules can be used independently or as an extension to the existing CAN network.
Digital information and analogue voltages can be detected as inputs and processed.
Application Examples
- Compact graphically programmable control unit for mobile applications
- Input and output extensions for CAN bus systems
- Connection of digital and analogue sensors via the CAN bus
General Information | |
---|---|
Connector | 9 pins DIN |
Dimensions | 30 x 30 x 40 mm |
Weight | ~ 35 g (High side), ~ 45 g (Relay) |
Operating temperature | -40 °C to 85 °C (no full load at 85 °C) |
Storage temperature | -40 °C to 85 °C |
Ingress protection | IP 53 |
EMC | E1 |
Operating voltage Vsupply |
9 to 30 V DC (High side version) 12 or 24 V DC (Relay version) |
Pre-fusing | up to 15 A (depending on load) |
Current consumption | 30 mA |
Processor type | Freescale HCS08 DZ60 |
Clock frequency | 40 MHz |
Flash memory | 60 kB |
RAM | 4 kB |
EEPROM | 1 kB available for graphical programming |
CAN Bus Interfaces | |
---|---|
Acc. ISO 11898-2 | High speed |
Acc. CAN 2.0 B | 29 Bits extended address identifier |
Acc. CAN 2.0 A | 11 Bits address identifier |
Baud rate |
20 kBit/s to 1000 kBit/s (125 kBits/s default value) |
Available inputs/ outputs | ||
---|---|---|
2 | Analogue inputs | 0-11.4 V DC 12 Bit |
2 |
Digital outputs Relay output |
High side outputs max 5 A OR changeover relay 10/15 A |
1 | Open collector output or Analogue input | max 2 W OR 0-11.4 V DC, 12 Bit |
Inputs / outputs details | |
---|---|
Analogue inputs | |
Input voltage max. | Vsupply |
Measuring range | 0-11.4 V DC |
Resolution | 12 Bit |
Input resistance | 22.6 kΩ |
Input frequency | max 100 Hz |
Digital outputs | |
Load current High side version |
max 3.5 A (2.5 A @ 80°C) max 5 A (load only on one channel) |
Load current Relay version | 10/15 A (O/C) |
PWM outputs | |
PWM frequency | max 1 kHz |
Duty cycle | 0 to 100 % |
Resolution | 0.1 % |
Load current | max 3 A |
Pin | Pin description | Function |
---|---|---|
1 | X | Analogue input 0-11.4 V |
2 | 30 | VCC Main Power Supply 9-30 V / 12 V / 24 V |
3 | C | Analogue input 0-11.4 V or Open collector output |
4 | 15 | Analogue input 0-11.4 V |
5 | 87A | Digital output (High side) / Relay output N.C. |
6 | 31 | Ground |
7 | H | CAN Bus High |
8 | 87 | Digital output (High side) / Relay output N.O. |
9 | L | CAN Bus Low |
Programming
Programming the ICCS Micro CAN is carried out using ICCS SDK Plus software.
In the development phase, we support you in the creation of programs.
If you prefer to create your parameters or create programs by yourself try our software development kit ICCS SDK Plus which you can borrow for three month free of charge.
Datasheet
- ICCS Micro CAN