ICCS 64P V2 CAN Controller
TheICCS 64P V2 Controller can be used as a standalone module or as part of the CAN network. It can perform logical functions or be used just as a I/O device. The module can drive loads up to 2 amps per output and has more than 30 inputs of different types.
The controller is the perfect complement to central electrical units and power boards from Würth Elektronik ICS. It can easily be connected to the printed circuit board and thus enables the control of the entire system, e.g. relay switching and monitoring of the fuse status via CAN bus.
The 16-bit processor (Freescale / NXP HCS12XEQ) with integrated co-processor has sufficient computing power to handle complex tasks. The two CAN interfaces and an optional LIN master interface allow data exchange between independent bus systems. In addition, the controller enables gateway / filter functions and the conversion of data from LIN battery management systems or LIN rain/light sensors to CAN bus.
Application examples
- Fuse monitoring and relay control
- Transmission of sensor values to the CAN bus
- CAN to CAN gateway functions
- LIN to CAN gateway functions
- Power supply of devices with low power consumption
- Interface between switches and CAN bus
General Information | |
---|---|
Housing | Transparent with black potting |
Connector | 4 x Molex Mini Fit 16 Ways |
Dimensions | 76 x 116 x 15 mm |
Weight | ~ 150 g |
Operating temperature | -40 °C to 85 °C (no full load at 85 °C) |
Storage temperature | -40 °C to 85 °C |
Ingress protection | IP54 |
Operating voltage Vsupply | 9 V to 30 V DC |
Pre-fusing | 10 A / block (HSD outputs) |
Current consumption | max 50 mA |
Processor type | Freescale / NXP HCS12XEQ |
Clock frequency | 100 MHz |
Flash memory | 384 kB |
RAM | 24 kB |
EEPROM | 1 kB available for graphical programming |
E1 certification | ECE10 Rev.05 : 058257 |
CAN Bus | |
---|---|
Acc. ISO 11898-2 | High speed |
Acc. ISO 11898-3 | Low speed (optional) |
Acc. CAN 2.0 A & B | 11 and 29 bits extended address identifier |
Baud rate |
20 kBit/s to 1000 kBit/s (125 kBit/s default value) |
LIN Bus (optional) | |
---|---|
LIN 2.1 master | Pull-up to Vsupply, 1 kΩ & diode |
Baud rate | 4800 to 115200 bps |
Vsupply | Recommended max 12 V (1 kΩ-12 V LIN) |
Available Inputs / Outputs | ||
---|---|---|
4 | Analogue inputs | 0 - 10 V DC / 0-20 mA |
3 | Analogue inputs | 0 - 10 V DC |
3 | Analogue inputs | 0 - 30 V DC |
4 | Analogue inputs | 0 - 5 V DC |
18 | Digital inputs |
Switch on / switch off level: see Inputs / outputs details |
4 | Digital / Frequency inputs |
Switch on / switch off level: see Inputs / outputs details |
8 |
Digital outputs or PWM outputs |
High side outputs max 2 A PWM outputs max 1 A |
8 | Digital outputs | High side outputs max 2 A |
Inputs / outputs details | |
---|---|
Analogue inputs |
3 x 0 - 10 V DC and 4 x 0 - 10 V DC / 0 - 20 mA |
Voltage / current | 0-11.4 V DC / 0-23 mA |
Resolution | 12 bits |
Input resistance | 22.6 kΩ |
Pull-down resistance | Switchable 0.5 kΩ in 0-20 mA mode (4x) |
Analogue inputs | 4 x 0-5 V DC |
Input voltage | 0-5 V DC |
Resolution | 12 bits |
Input resistance |
High-Z through op. amp. |
Analogue inputs | 3 x 0-30 V DC |
Input voltage | 0-33.6 V DC |
Resolution | 12 bits |
Input resistance | 66.6 kΩ |
Digital inputs | 18 |
Input voltage | 0 V DC to Vsupply |
Switch-on level | 7 V DC |
Switch-off level | 4 V DC |
Input resistance | 22.6 kΩ |
Frequency inputs | 4 |
Input resistance | 100 kΩ |
Input frequency | 5 KHz |
Digital outputs | 16 x High side |
Load current |
max 2 A Diagnostic current sense, freewheel diode |
PWM outputs | max 8 of digital outputs |
PWM frequency | max 1 kHz |
Duty cycle | 0 to 100 % |
Resolution | 0.10 % |
Load current | max 1 A |
5 V supply | Switchable from SW |
Max current | 400 mA |
Mating connector | Part number WE eiSos |
---|---|
Housing: Female Dual Row Plug WR-MPC4 | 649 016 113 322 |
Crimp contact: WR-MCP4, AWG 16 (1.31 mm²) | 649 005 137 22 |
Crimp contact: WR-MCP4, AWG 24-18 (0.2 to 0.82 mm²) | 649 006 137 22 |
Crimp contact: WR-MCP4, AWG 28-22 (0.08 to 0.33 mm²) | 649 007 137 22 |
For 100 pieces packages, please add "DEC" at the end of the reference. |
Programming
Programming the ICCS 64P V2 CAN Controller is carried out using ICCS SDK Plus software.
In the development phase, we support you in the creation of programs.
If you prefer to create your parameters or create programs by yourself try our software development kit ICCS SDK Plus which you can borrow for three month free of charge.
Datasheet
- ICCS 64P V2 CAN Controller
(PDF, 635KB)